How to update the xsd file c #

How to update standard parts in an assembly

Error: Part file could not be created. You do not have read / write permission to the location of the Content Center files.
The part file (.ipt) is write-protected and cannot be replaced by a newer version. The file was locked by a file control system or manually set as read-only.

Change the status of the part file to read / write and invoke the Update Standard Components command again.

Error: Part file could not be created. An existing component file with the same name that belongs to a different family variant was found in the family folder.
The file name of the updated standard component is not unique within the relevant family or originally belonged to a different family variant. The part file with the current file name cannot be created.

Change the File Name property for the family variant. Then invoke the Update Standard Components command. A new part file with the new file name is instantiated for the updated part.

Error: Part file could not be created. An existing part file with the same name that is from a different family was found in the family folder.
The file name of the updated standard part is not unique within the current family folder. The part file cannot be created in the current folder.

Change the Family Folder Name or File Name property for the appropriate family. Then invoke the Update Standard Components command. A new part file with the new file name or in the new family folder is instantiated for the updated part.

Error: Part file could not be created. The name of the part file exceeds the maximum path length.
The path length including the part file name exceeds 252 characters. The component cannot be instantiated.

Change the Family Folder Name or Filename property for the family to shorten the path length. Then call the Update Standard Components command again.

Error: Part file could not be created. Suppressing or unsuppressing one or more items failed.
The part cannot be created due to problems in the part geometry. For example, the model was edited after it was instantiated in the assembly.

Correct the geometry parameters in the family table and family template to resolve the problem. Then call the Update Standard Components command again.

Error: Part file could not be created. No thread or hole feature was found in the component template.
Parameters in the family table do not match parameters in the family template. Some geometric parameters from the table are missing from the template.

Correct the template or family table. Then call the Update Standard Components command again.

Error: Part file could not be created. Thread or hole feature could not be created.
The geometry parameters for the thread or hole feature in the family table are not correct to create the feature.

Correct the thread or hole parameters in the family table and invoke the Update Standard Components command again.

Error: Part file could not be created. Wrong parameter value.
The current value of a custom parameter for the instantiated family member is out of the range for the custom parameter. The range of the custom parameter was changed after the family variant was instantiated.

Correct the range of the custom parameter in the family table and invoke the Update Standard Components command again. Alternatively, replace the current component with a new Content Center component.

Error: Material could not be set.
There is no information available about the material of the standard component. The material specified for the family variant in the library must be in the material library list.

Correct the information about the material in the Content Center Library or in the Material Library. Then call the Update Standard Components command again.

Error: New part file was created successfully. However, the replacement operation in the assembly failed.
The family member instantiated successfully, but the link between the updated part file and the assembly failed.

Manually replace the component in the assembly. Use the Replace Component command to replace the original standard component with the new instance from the data carrier.

Error: Unable to check out from vault.
Check the status of the standard part file in Autodesk Vault Basic.
Error: The pipe component is owned by Tube & Pipe. The component must be updated from the Tube & Pipe application.
The part file cannot be updated with the Update Standard Components command because the file contains additional edits made by Tube & Pipe. Use the Pipe and Pipe commands to update the standard part.
Error: The owner of the standard is Tube & Pipe. The component must be updated from the Tube & Pipe application.
The Tube & Pipe add-on module must be loaded in order to update this component.

Load the Pipe and Pipe add-on module and run Update Standard Components again.

Error: Part file could not be created. Unknown error.
The part file was not updated because the instantiation of the standard part failed for an unknown reason.

Review the part file and family information in the library.

Error: Unknown error.
The part file was not updated for an unknown reason.

Review the part file and family information in the library.

Warning: Part family is marked as 'damaged'. Check the part file.
The component family is marked as damaged in the library. A member of a damaged family can be instantiated, but the instantiated part can be damaged.

Correct the family and then update the standard component again.